NOTE: An activated carbon cartridge (Taste/Odor) may contain a small amount
of carbon fines (very fine black powder) and a new cartridge, after installation,
should be flushed with sufficient water to remove the fines before using the
water. Each time you use your water from your filtered water tap for drinking or
cooking purposes, it is recommended that you run (flush) the tap at least 10
seconds prior to using water. This is particularly important if the water tap is not
used daily.
NOTE: Certain types of harmless bacteria will attack cellulose material.
Cartridges containing cellulose may seem to disintegrate, produce a “musty” or
“moldy” odor, or form a black precipitate due to the bacteria. If you notice any of
the above problems while using the cellulose media cartridge, switch to a
synthetic media cartridge or consult the manufacturer.
NOTE: The replacement cartridge has a limited service life. Exhaustion of the
service life of those parts often cannot be easily detected. Commonly, it is only
after leakage has been observed or water damage has occurred that one is
made aware that the service life has been exhausted.
IMPORTANT NOTICE: To prevent costly repairs or possible water damage we
strongly recommend that the bowl or sump of all plastic housings be replaced
periodically: every five years for clear sumps, and every ten years for opaque
sumps. If your sump has been used for more than that the recommended period,
it should be replaced immediately. Be sure to date any new or replacement sump
for future reference and indicate the next recommended replacement date.
Cleaning UV 110
The quartz sleeve should be cleaned with warm soap and water every three
months.
UV bulb should be replaced every 9-12 months. The bulb does not normally burn
out, however the efficiency of the bulb decreases after one year.
Contact your local water treatment professional for replacement cartridge and
bulb pricing or call 1-800-645-0267 for a dealer near you.
Replacing UV Lamp and Filter
To ensure optimal performance from your PuriFire™ system and to protect your
warranty, use only genuine PuriFire™ filters and lamps available from your
PuriFire™ dealer.
UV lamp replacement
1. Turn off all electrical power to the system by unplugging or throwing the circuit.
2. Unscrew the UV control module from the mounting bracket (4 screws) for
Models UV-110
3. Slide the old bulb out and unplug from the control module.
NOTE: Hold the UV lamp only by the plastic covered ends of the bulb.